Biomekka 1.8.42 - Heatwave mode Base: 1.8.41 TRICKLE 5S REASSERT. Changes: - Added emergency heatwave fan mode. - Heatwave fan mode turns on at 27.0C air/water and releases only after air <= 26.5C and both water probes < 27.0C. - Main fan is treated as circulation and ramps 60/80/100%. - Small fan is treated as exhaust and ramps 35/60/85/100%. - Front glass/demist fan is pushed to 90/95/100% during heatwave. - Heatwave fan mode overrides mist wind lock and pre-storm fan behaviour because heat protection wins. - Ceramic and back heaters are forced OFF while heatwave fan mode is active. - Addressable LEDs and COB are blacked out from 28.0C worst air/water temp, with release at 27.5C. - Added heatwave flags to dashboard JSON and serial status block. Unchanged: - Trickle schedule remains 5s ON every 3min with ON reassert. - Goblin pin mapping unchanged. - Storm timing/eligibility unchanged. - Sensor addresses unchanged.